Warning: Trying to access array offset on false in /home3/indiakep/public_html/wp-content/plugins/dw-question-answer/inc/Template.php on line 8
1 Answers
- Parameter Group Number represents the identifier of a J1939 message.
- Every J1939 message has a unique PGN assigned to it by the SAE committee when the message is defined.
- A PGN is 18-bits wide and is made up of the following fields:
- Extended Data Page, Data Page, PDU Format
- Depending on the value of the PDU Format field, a message is either destination-specific, meaning it is for a specific node.